Brugger is a specialist in the quality control of films in the food, pharmaceutical and packaging industry since 1860. We offer permeation testers for gas and steam, thermal contact sealing devices and testing devices for determining the sealed seam properties as well as other special film testing devices. We do everything we can to meet the highest standards – our own. Eurotech also offers Brugger-Certified Calibration Services for in-field equipment.
Quick answers for US and North American buyers
Where can I buy a seal strength or peel tester in the US?
Eurotech Direct is the North American contact for Brugger film testing equipment and supplies the line from Richfield, Ohio. For seal strength, the Brugger instrument is the VNG-E universal tensile tester, which is designed to measure laminate bond strength and seal strength in films. Seals are usually made first on the HSG-CC or NDS heat sealer, with test strips cut on the STR. Email [email protected] with your material and test method to talk through the right setup.
Which Brugger tester measures gas permeability?
The Brugger GTT and GDP-C are the gas permeability testers in the range, and both measure how readily gas passes through a film using a manometric differential-pressure method. The GTT runs from a built-in touch panel and controls sample temperature on the instrument from 15 to 45 °C. The GDP-C uses a PC and an external bath thermostat, which gives it a wider sample-temperature span of −20 to 80 °C. If you also want to see whether flexing changes the barrier, the KFT-C preconditions the film before you test it again on either instrument.
Does the Brugger VNG-E measure gas permeability?
No, the VNG-E is a tensile tester, not a gas permeability tester. It is built mainly to measure laminate bond strength, seal strength, and friction of films, and it also covers tensile properties. For gas permeability, look at the GTT or the GDP-C.
More About Brugger Feinmechanik
SEALING TESTING
PERMEATION TESTING
MECHANICAL TESTING
SAMPLE PREPARATION
OPTIONAL ACCESSORIES
Brugger film testing equipment: how to choose
What does Brugger film testing equipment cover?
Brugger film testing equipment is laboratory gear for quality control and R&D of films used in food, pharmaceutical, and packaging work. On this page the range splits into sealing testers, gas permeation testers, mechanical testers, sample preparation, and accessories for the heat-sealing system. Brugger has built film testing devices for that kind of lab work for decades; Eurotech Direct is the North American contact and also offers Brugger-certified calibration for equipment already in the field. This FAQ helps you choose a path. Exact configuration still depends on your material and method.
Which Brugger instrument should I choose for my main task?
Match the instrument to the main task, then add the usual partner tools. Heat sealability and sealing parameters: HSG-CC, often with the STR strip cutter, the VNG-E tensile tester, and optional Hot Tack and HSG-P. Low-pressure sealing of pressure-sensitive packaged goods: NDS, typically with STR and VNG-E. Gas permeability with temperature control built into the instrument: GTT. Gas permeability over a wider temperature range using an external bath: GDP-C. Both permeation testers pair with the KFT-C when you need to flex the film first. Seal strength, laminate bond, tensile properties, Young’s modulus, and friction: VNG-E, using specimens from the HSG-CC or NDS. Durability of handles and grips: TPG-U. Accurate specimen strips: STR. Strength of a seal while it is still hot: Hot Tack on the HSG series. Checking temperature, force, and time on an HSG heat sealer: HSG-P. If more than one task matters, use the workflow answers below instead of buying a single “do everything” unit.
What is the difference between the Brugger HSG-CC and the NDS?
The HSG-CC is a laboratory contact heat sealer for reproducible seals under defined temperature, force, and time. Brugger’s data sheet describes that testing in line with ASTM F2029-16. It is the usual choice when you need an adjustable sealing force and interchangeable jaws to find a sealing window. The NDS is for sealability at very low pressure, set with weights rather than a powered force range. It has five sealing stations that can run at different temperatures in one cycle, which is aimed at pressure-sensitive packaged goods. Choose the HSG-CC for broader process simulation. Choose the NDS when the question is low-pressure sealability and a temperature profile. Neither machine measures how strong the cooled seal is; that is a VNG-E test after you seal.
What is the difference between the Brugger GTT and the GDP-C?
Both instruments measure how readily gas passes through a film, using a manometric differential-pressure method. The GTT follows ISO 15105-1, is run from a built-in touch panel, and controls sample temperature on the instrument from 15 to 45 °C, so you do not need an external water bath for that range. The GDP-C uses a Windows PC for analysis and an external bath thermostat, which is what gives it a much wider sample-temperature span, from −20 to 80 °C. The GDP-C data sheet cites ISO 15105-1 and ASTM D1434-82(2015), Procedure M. Pick the GDP-C when you must test well below 15 °C or above 45 °C, or you already have a suitable bath. Pick the GTT when you want the more compact setup with temperature control included. For most other spec questions, use the product pages.
How do labs combine Brugger instruments to develop and check a heat seal?
For a normal sealing window, prepare uniform strips on the STR, seal them on the HSG-CC at defined temperature, force, and time, then measure cooled seal strength on the VNG-E. Hot Tack is optional and answers a different question: how strong the seal is immediately after sealing, while it is still hot. It is an HSG accessory, not a replacement for the VNG-E. The HSG-P is only for checking the sealer’s temperature, force, and time. For pressure-sensitive goods the order changes: seal on the NDS first (five temperatures, one sealing time, low pressure by weights), cut specimens on the STR, then compare seal strength on the VNG-E.
How do labs check whether flexing changes a film’s gas barrier?
The KFT-C does not measure gas permeability. It preconditions flexible barrier films by repeated compression and twisting (Gelbo flex) under ASTM F392-93 conditions A through E. The usual workflow is to measure gas permeability on the GTT or the GDP-C, flex the specimen on the KFT-C, then measure the same way again and compare the change. Use the GTT or the GDP-C based on the temperature range you need, not because one of them “includes” flex testing.
What is Hot Tack, and when is the Brugger Hot Tack fixture used?
Hot Tack is the strength of a seal right after heat sealing, while the sealant is still hot. That matters on high-speed packaging lines, where the seal is loaded before it has fully cooled. The Brugger Hot Tack fixture is an accessory for the HSG series, especially the HSG-CC, and it refers to DIN 55571-1. It is a qualitative check of the fresh seal, not a seal-strength result in newtons. Cooled seal strength is still measured on the VNG-E. Strips for the fixture are typically cut on the STR. The fixture is not used at the same time as the semi-automatic sample feeder; the HSG-CC is set up for one or the other.
Why should we discuss the Brugger configuration before ordering?
The right Brugger setup depends on the material, the test standard, the measuring range, sample geometry, and how results must be documented. Jaw style, whether you need Hot Tack, which permeation temperature range you need, and whether a flex-then-retest workflow applies all change the quotation. Eurotech recommends an application discussion before you order so the instrument matches the test you will actually run. Contact Eurotech Direct with the material, the standard you must follow, and the property you need to measure (seal window, low-pressure sealability, gas barrier, seal strength, or handle durability).
What Brugger support does Eurotech offer in North America?
Eurotech Direct supplies this line from Richfield, Ohio, and the hub states that Eurotech offers Brugger-certified calibration services for in-field equipment. Maintenance is done in a qualified workshop and includes calibrating the instrument so it stays inside its specified performance; you receive a test or acceptance report when the work is finished. Repairs are quoted first, then carried out in that workshop, again with a test or acceptance report. Damaged sealing jaws can in most cases be reworked. To limit downtime you can request a loaner while an instrument is in for maintenance or repair. Eurotech also rents the HSG-P calibration system so you can check an HSG heat sealer on your own premises. Separate from calibration, the hub describes permeation training (with a certificate) and, if you need it, installation and commissioning in your lab with instruction included. Call +1.330.467.0205 or email [email protected], Monday through Friday, 8:00 a.m. to 5:00 p.m.
Which Brugger tester is for film strength, and which is for handles?
The VNG-E is the universal tensile tester for flexible materials. Labs use it for laminate bond strength, cooled seal strength, friction, and tensile properties including Young’s modulus, usually on strips cut with the STR and often on seals made with the HSG-CC or NDS. The TPG-U is for a different job: repeated up-and-down loading of carrying handles and grips on bags and outer packaging. It does not replace a film tensile test. If a pack has both a seal and a handle, you may need both instruments; the seal path is still HSG-CC or NDS, then VNG-E, while the handle path is the TPG-U.
Does a Brugger heat sealer also measure seal strength?
No. The HSG-CC and the NDS make the seal under controlled conditions. Mechanical strength of the cooled seal is measured afterward on the VNG-E. The STR is there so those specimens are cut to a consistent width. Hot Tack, if you need it, only describes the seal while it is still hot and is not the cooled strength test.
When do we use the HSG-P instead of sending the heat sealer in?
The HSG-P is a portable check of temperature, force, and time for Brugger HSG heat sealers (the data sheet lists the HSG-CC, HSG-C, and HSG-ETK). It is for in-house monitoring and troubleshooting of those sealers. It is not listed for the NDS. It does not replace the calibration and traceability your own quality system requires, and it is not a substitute for workshop maintenance. Eurotech’s Brugger-certified calibration and workshop maintenance are the service route; the hub also offers HSG-P rental so you can run that check on site. Ask Eurotech which option fits the sealer you have.
Need help choosing the right film testing equipment for your line?
Contact Eurotech Direct: +1.330.467.0205 · [email protected]
Our Services
Maintenance
We carry out all necessary maintenance work on your test instrument in our qualified workshop. This includes calibrating the device to ensure precise functionality and fulfill your regular test equipment monitoring.
A test or acceptance report, which is issued on completion of the maintenance work, guarantees that your test instrument is fully operational within the given instrument specifications.
Repairs
After preparing a detailed cost estimate, our qualified workshop will carry out all necessary repair work on your test instrument. A test or acceptance report, which is issued on completion of the repair work, guarantees that your test instrument is once again fully operational within the given instrument specifications.
Scratched, burnt or otherwise damaged sealing jaws can in most cases be reworked to such an extent that they once again meet the quality standard of new sealing tools.
Equipment on Loan
In order to maintain the smoothest possible operation, you can request a loaner from us for the period of maintenance or repair.
We also offer a rental service for the HSG-P calibration system, so that you can check your HSG heat sealer on your premises.
Our office will be pleased to inform you about further details.
Custom-Made Products
We can manufacture sealing jaws (up to 150mm x 25mm) with almost any surface to suit your requirements.
The measuring range of our GDP-C and GTT permeation testers can be shifted upwards by one or two orders of magnitude for new devices.
The documentation software of our testing devices with Microsoft ACCESS interface can be adapted to your requirements.
Training
For the demanding field of permeation measurement, we offer special training courses on this subject. The specialist knowledge acquired about the physical processes and the measuring method used in our devices enables you to correctly interpret the measured values obtained. Upon completion of the training, participants receive a corresponding training certificate.
Installation
If required, we can also carry out the installation and commissioning of our test equipment in your laboratory. Instruction in the operation of our equipment is included. Following installation, we always recommend a detailed and individual training course to prepare your laboratory personnel optimally for future measurements.
Interested? We look forward to your request.
So, need help choosing the right film testing equipment for your line? Our team is ready to help.